REGULATORY SAMPLING โ LEAD, MERESIDE WATER, 2032 Samples taken at consumer taps: 2,840. Selection: random, stratified by water supply zone, from the full property list. Compliance: 2,831 of 2,840 (99.68%). Exceedances of 10 ยตg/l: 9. Properties in supply area with lead in the service pipe (modelled): 218,000 (15.6%). Expected number of lead-pipe properties in a random sample of 2,840: about 443. Observed samples returning above 5 ยตg/l: 71. Above 3 ยตg/l: 188. Sampling is random daytime, without prior flushing or stagnation control. First-draw sampling is not part of the regulatory regime.
Ninety-nine point six eight per cent compliant. Nine exceedances out of two thousand eight hundred and forty.
That is a true figure, correctly calculated, reported to the regulator, published, and it is the number by which my company's lead performance is judged.
What random daytime sampling measures
Water that happens to be in the pipe when the sampler arrives.
Lead dissolves into water that is standing in a lead pipe. A tap that has been used ten minutes ago contains water that has been in the lead for ten minutes. A tap that has not been used since the night before contains water that has been in the lead for eight hours.
Random daytime sampling catches a mixture, weighted towards recently-used taps, because samplers arrive in the working day at houses where somebody is in.
It is a reasonable estimator of average exposure across a population and it is a poor estimator of the exposure that matters, which is the first glass of the morning, in the kitchen, made into a bottle of formula.
Why the regime is built that way
Because it has to be comparable, repeatable and affordable across a whole country.
First-draw sampling โ requiring an unused tap after a specified stagnation period โ gives a much higher and much more meaningful figure, and it requires the occupier to follow instructions precisely on a specified morning. It is used for investigations, not for compliance.
Random daytime is the honest compromise between a measurement that means something and a measurement you can actually take two thousand eight hundred and forty times a year. I would not replace it for compliance purposes and I have said so to the regulator.
The four hundred and forty-three
In a random sample of two thousand eight hundred and forty properties from a stock that is fifteen point six per cent lead, about four hundred and forty-three of the samples come from lead properties.
Nine of them exceeded. So the compliance figure is overwhelmingly a measurement of the eighty-four per cent of properties that have no lead in them at all, and the signal from the two hundred and eighteen thousand that do is diluted to the point of near-invisibility.
I can compute the lead-property subset. I did, in 2031. Among samples from properties we believe have lead, the exceedance rate is about two per cent and the mean is 3.4 micrograms per litre โ four times the mean of the non-lead stock.
That subset figure appears in no return, because the return is a supply-area compliance percentage, and nobody has ever asked me for it.
What the standard is, and what it is not
Ten micrograms per litre at a consumer tap is a compliance standard for a water supply. It is not a safe level, and the guidance says so: there is no safe level of lead.
So a property at eight micrograms is compliant and is delivering lead to a child every day. 2B Glenvarra Road at eighteen was non-compliant; at six, in February 2034, it became compliant, and Dev Dhillon is still drinking lead.
Ninety-nine point six eight per cent of my samples comply, and every one of my two hundred and eighteen thousand lead properties is delivering some lead to somebody, and both of those sentences are true and only one of them is reported.