EXTERNAL WALL FIRE REVIEW โ CARROW POINT, SALTGATE. ISSUED 14 JUNE 2032 Building: 14 storeys, 96 flats, completed 2008. External wall: thin-coat render on expanded polystyrene insulation; timber-framed balconies; masonry inner leaf. Evidence available: visual inspection from ground and from 4 balconies; 2 intrusive openings; no as-built drawings; no product identification; no cavity barrier records. Findings at the 2 openings: 90 mm expanded polystyrene; no cavity barrier present at either location. Assessment outcome: UNABLE TO CONFIRM that the external wall construction meets the relevant standard, on the evidence available. Further investigation required for a conclusive assessment: 22 openings, all elevations and junction types, with laboratory identification. Estimated cost ยฃ186,000. Assessor: I. Halsall CEng MIFireE. Fee for this review: ยฃ1,400.
Fourteen hundred pounds. A hundred and eighty-six thousand pounds to answer the question properly. And a form that says the only honest thing I am able to say.
What "unable to confirm" means
That I have not seen enough of the wall to say whether it is adequate.
It does not mean the wall is dangerous. It does not mean I found anything wrong โ at the two places we opened up, the construction was ordinary for 2008 and the absence of cavity barriers at those two locations is a finding about two locations.
It means I do not know, and the reason I do not know is that nobody has paid for twenty-two openings.
And what it does
Ninety-six flats at Carrow Point cannot be sold. No lender on the panel used by any of the big valuation firms will lend against a flat whose building's external wall review says unable to confirm. Not at a reduced valuation; at nil.
Three leaseholders have had sales fall through since I issued it. One has declined a job in Leeds. The building's insurance premium per flat has gone from three hundred and ten pounds to fourteen hundred and ten.
I wrote the most carefully hedged professional opinion of my career and the market read it as "unsafe", which is not what it says and is the only thing it could mean to somebody deciding whether to lend two hundred thousand pounds.
Who I am
Ingrid Halsall. I am forty-six, a chartered fire engineer, and a director of a practice of nine people in the north of England. I have done this for twenty-two years, the last twelve of them mostly on existing buildings.
My practice has issued two hundred and twelve external wall reviews since 2021. Adequate: seventy-four. Remediation required: fifty-eight. Unable to confirm, on the evidence available: eighty.
Eighty buildings. The median time they have been in that condition is three years and four months.
The number that made me write this
Of those eighty, twenty-three have since found the money for a full intrusive investigation.
Seventeen of the twenty-three turned out to be adequate. Six needed work, two of them urgently.
So seventy-four per cent of the buildings I could not confirm were fine all along โ and their leaseholders spent an average of three years unable to sell, remortgage or move, at insurance premiums four times what they were, because the only outcome available to me was a sentence that the mortgage market reads as a condemnation.
What I am not going to argue
That I should sign things I cannot evidence. Seventy-two people died at Grenfell Tower and a great many of the documents in that story were signed by people who had not looked.
That the liability is unfair. It is the only reason assessments in this sector are careful, including mine.
That lenders are behaving unreasonably. They are being asked to secure a loan against an asset with an unquantified risk and no insurance behind the opinion, and they are doing the rational thing.
The argument is that a regime with two outcomes forces a third condition into one of them, and the one it goes into is the wrong one, and nobody chose that.