QUOTED COST โ continuous effluent monitoring, works of Hazelby's size (2035 figures, from the operator's framework) Instrument (ammonia analyser, turbidity, DO, flow-linked), installed, with kiosk, power and telemetry: ยฃ47,000. Annual maintenance, reagents, calibration, data management: ยฃ11,400. Across my 203 spot-sampled consents: capital ยฃ9.5m, annual ยฃ2.3m. Across the country, at roughly 9,000 water company works alone: capital in the region of ยฃ420m.
Those are the real numbers and they are why it is nine and not two hundred and twelve.
Why it is not simply worth it
It may well be worth it. I think at the larger works it plainly is. But the honest case has to deal with three things that the straightforward "install monitors" argument skips.
Most consents are tiny. Of my 203, a hundred and forty-one serve populations under two thousand โ a village works, a package plant behind a pub, a caravan site. Forty-seven thousand pounds of instrumentation on a works serving four hundred people is a cost per head that no regulator could justify and no bill payer would accept, and the environmental benefit is correspondingly small because the discharge is small.
The instruments are not as good as people think. An ammonia analyser in a sewage effluent channel is a wet chemistry instrument living in a hostile place. It fouls. It drifts. It needs calibrating monthly and servicing quarterly, and when it is out of service you have a permit condition you cannot comply with, which creates its own enforcement problem. My nine continuous monitors had a combined availability last year of eighty-four per cent.
And the money comes from somewhere. Water company investment is recovered from customer bills. Four hundred and twenty million pounds nationally is a real sum taken from real households, and the people arguing hardest for continuous monitoring everywhere are rarely the people who will explain that trade-off at a hearing.
Where it is obviously right
At works above about ten thousand population equivalent discharging to a sensitive water, continuous monitoring is cheap relative to the harm and the operator usually has telemetry already. Hazelby serves twelve thousand two hundred and discharges to a designated fishery, and on any reading of the numbers it should have it.
I said so in 2031 when I varied the permit, in a paragraph of my determination note, and it was not pursued, and I did not push it, because the works was performing well against its limits and there was nothing to point at.
Which is the whole problem stated in one sentence: the case for measuring something properly is hard to make while the inadequate measure is returning good results.
What I am asking for instead
Not two hundred and three instruments. Chapter Fifteen is a great deal smaller than that, and it exists because I accept everything in this chapter.